规格书 |
|
工业别名 |
785901913443, XCSDMP790L01M12 |
子类别 |
Switch Safety Interlock |
交货期 |
14 Days |
深度 |
13mm |
外形尺寸 |
88 x 25 x 13 mm |
外壳材料 |
Thermoplastic PBT |
IP等级 |
IP67 |
长度 |
88mm |
方针路线数 |
3 |
电源电压 |
24 V dc |
开关距离为8mm |
8 mm |
宽度 |
25mm |
RoHS指令 |
Compliant |
开关类型 |
Saftey |
product certifications |
BGCSAUL |
vibration resistance |
10 gn (f = 10...150 Hz) conforming to IEC 60068-2-6 |
product weight |
0.18 kg |
cable material |
PVC |
[Ie] rated operational current |
<= 100 A |
contacts material |
Rhodium |
connector type |
M12 |
insulation resistance |
1000 MOhm |
design |
Rectangular, standard |
switching capacity in mA |
0.1...100 mA |
standards |
CSA C22-2 No 14EN/IEC 60204-1EN/IEC 60947-5-1EN/ISO 12100UL 508 |
shock resistance |
30 gn for 11 ms conforming to IEC 60068-2-27 |
maximum switching voltage |
100 V DC |
product or component type |
Coded magnetic switch |
sensitivity to magnetic fields |
>= 0.3 mT |
class of protection against electric shock |
Class II conforming to IEC 60536 |
safety reliability data |
B10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear) |
[Sa] assured operating distance |
8 mm |
component name |
XCSDMP |
resistance across terminals |
10 Ohm |
protective treatment |
TH |
switching frequency |
150 Hz |
size |
88 x 25 x 13 mm |
safety level |
Can reach category 4 (with the appropriate monitoring system and correctly wired) conforming to EN/ISO 13849-1Can reach PL = e (with the appropriate monitoring system and correctly wired) conforming to EN/ISO 13849-1Can reach SIL 3 (with the appropriate monitoring system and correctly wired) conforming to EN/IEC 61508 |
contacts type and composition |
2 NC |
contacts operation |
Staggered |
range of product |
Preventa Safety detection |
ambient air temperature for operation |
-25...85 °C |
material |
Plastic |
IP degree of protection |
IP67 conforming to IEC 60529 |
approach directions |
3 directions |
[Sar] assured tripping distance |
20 mm |
enclosure material |
Thermoplastic PBT |
[Uimp] rated impulse withstand voltage |
2.5 kV conforming to EN/IEC 60947-5-1 |
[Ue] rated operational voltage |
24 V DC |
electrical connection |
Connector on flying lead |
short circuit protection |
500 mA external cartridge fuse type gG (gl) |
cable length |
0.15 m |
[Ui] rated insulation voltage |
100 V DC |
ambient air temperature for storage |
-40...85 °C |
breaking capacity |
<= 10 VA |
number of poles |
2 |
electrical durability |
1200000 cycles |